KTD-S0022-C Page 49 Appendix A: System Resources
KTLX800/pITX User's Guide
A.4 PCI Devices
All devices follow the Peripheral Component Interconnect 2.2 (PCI 2.2) specification. Please see the speci-
fication for more details.
PCI Device PCI IRQ Comment
Host Bridge None Chipset
Graphics Controller INTA Chipset
ISA Bridge None Chipset
S-ATA Controller None Chipset P TA attachment -A
USB 1.1 Controller INTD Chipset
USB 2.0 Controller INTD Chipset
LAN Controller INTC PCI bus (AD19)
A.5 System Management Bus (SMBus
TM
)
The KTLX800/pITX uses an onboard System Management Bus (SMBus
TM
). This bus is not available on a peri-
heral connector and therefore cannot be used for external SMBus
TM
devices.
p
SMBus
TM
Address Device Comment
98h / 99h Temperature sensor Write access allowed
A0h / A1h SPD Eeprom (DDR-SDRAM)
A8h / A9h Kontron specific / DisplayID
Warning: s c MBus
TM
than li in thi t access to these devices in not permitted. There are more device onnected to the S sted s table bu
Don’t access any other de xcept those list ove. vice addresses e ed ab