Kontron User's Guide ETXexpress® CD
5 Special Features
5.1 Watchdog Timer
This feature is implemented in the Xilinx XC9536XL microcontroller. You can configure the Watchdog
Timer (WDT) in BIOS setup to start after a set amount of time after power-on boot. The WDT can also be
controlled by the JIDA32 Library API (Refer to Appendix F: JIDA Standard). The application software
should strobe the WDT to prevent its timeout. Upon timeout, the WDT resets and restarts the system. This
provides a way to recover from program crashes or lockups.
Configuration
You can program the timeout period for the watchdog timer in two ranges:
1-second increments from 1 to 255 seconds
1-minute increments from 1 to 255 minutes
Contact Kontron Embedded Modules technical support for information on programming and operating
the WDT.
5.2 General Purpose Input and Output
COMe-bCD2 offers 4 General Purpose Input (GPI) pins and 4 General Purpose Output (GPO) pins. On a
3.3V level digital in- and outputs are available.
Configuration
The GPI and GPO pins can be configured via JIDA32. Please refer to the JIDA32 manual in the driver
download packet on our website.
Komentarze do niniejszej Instrukcji