Kontron MOPSlcdLX Instrukcja Użytkownika Strona 32

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 54
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 31
KTD-S0005-C Page 28 Crisis Management
MOPSlcdLX User's Guide
18 Crisis Management
Modifying parameters in the BIOS Setup implies the risk of leaving your system in a unbootable state. In
case this happens two jumper exists to reset the settings to 'Fail-Safe values'.
In case no battery is connected then follow these five steps:
Power down the system
Remove the tagged jumper JP14002 (see the picture)
Power up the system and enter the BIOS Setup
Before saving your new settings with 'Save & Exit' put the jumper back
The board should be functional now
In case there is a backup battery for the real time clock:
Power down the system
Switch the second jumper JP7000 as depicted and wait for 3 seconds
Put the jumper back as it was before
Then continue with the steps from the no battery case.
Przeglądanie stron 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 53 54

Komentarze do niniejszej Instrukcji

Brak uwag