KTQM77 KTHM76 Users Guide
KTD-N0850-F Page 24
b) Low Power Setup KTQM77/mITX +12V only PSU TBD
DOS Idle, Mean, No external load
Supply
Current draw
[A]
Power consumption
[W]
+12V P4
1,721
20,652
Total
20,7
Windows 7, mean
3DMARK2005 ( first scene ) & BiT 6
Supply
Current draw
[A]
Power consumption
[W]
+12V P4
3,940
47,28
Total
47,3
S0 Mode, Mean, No external load
Supply
Current draw
[A]
Power consumption
[W]
+12V P4
0,992
11,904
Total
11,9
S3 Mode, Mean, No external load
Supply
Current draw
[A]
Power consumption
[W]
+12V P4
0,099
1,188
Total
1,19
S5 Mode, Mean, No external load
Supply
Current draw
[A]
Power consumption
[W]
+12V P4
0,098
1,176
Total
1,18
System Specification