KTD-S0018-0 Page 4 JILI30 Connector (SBC Side)
Display Cable Guide
3 JILI30 Connector (SBC Side)
It's a single row connector with 30 contacts and 1.0 mm pitch (JAE, FI-X30S-HF or equivalent).
Header Pin Signal Name Function
1 FTX0- First channel data 0 output (negative)
2 FTX0+ First channel data 0 output (positive)
3 FTX1- First channel data 1 output (negative)
4 FTX1+ First channel data 1 output (positive)
5 FTX2- First channel data 2 output (negative)
6 FTX2+ First channel data 2 output (positive)
7 GND Ground
8 FTXC- First channel clock output (negative)
9 FTXC+ First channel clock output (positive)
10 FTX3- First channel data 3 output (negative)
11 FTX3+ First channel data 3 output (positive)
12 STX0- Second channel data 0 output (negative)
13 STX0+ Second channel data 0 output (positive)
14 GND Ground
15 STX1- Second channel data 1 output (negative)
16 STX1+ Second channel data 1 output (positive)
17 GND Ground
18 STX2- Second channel data 2 output (negative)
19 STX2+ Second channel data 2 output (positive)
20 STXC- Second channel clock output (negative)
21 STXC+ Second channel clock output (positive)
22 STX3- Second channel data 3 output (negative)
23 STX3+ Second channel data 3 output (positive)
24 GND Ground
25 SDA I2C data line
26 DATAENA
Designator badly chosen - means:
Panel power enable (power sequencing)
27 SCL I2C clock line
1
3
0
28 - 30 VCC Power +3.3V or +5.0V