CPCI Backplane PD18: CP6-BP4-PB-RIO
RID 24229 PD18, Rev. 01 © 2003 PEP Modular Computers GmbH Page 3
1. Introduction
The specific product description provided with this product documentation is part of the PEP’s
CPCI Backplane manual. For further information, in particular regarding general details as well
as safety and warranty statements, refer to the CPCI Backplane Manual, ID 24229.
2. CP6-BP4-PB-RIO Power Bar Backplane
The main features of the 6U, 4-slot, power bar backplane CP6-BP4-PB-RIO are described in
the following table:
Table 1: Distinctive Features of Backplane CP6-BP4-PB-RIO
Feature Specification
Form Factor
6U
Size
95.5*262.05 mm
Number of Slots
4
Bus Resolution
64 bits
Bus Frequency
33 or 66MHz
Rear I/O Connectivity
P3 to P5 on all slots
Hot-Swap Capability
Yes
Power Supply Connector
11 power bar terminals, M3 lugs
Redundant Power Supply
System Management
Optional
Flexible Grounding Option
Yes
Fan Connector
Optional
MSD Connector
Optional
Power LED
PS-ON Connector
Yes
System MON-CTRL Connector
Yes