COMe-cSP2 / Design Consideration
53
6 Design Consideration
6.1 Thermal Management
A heat-spreader plate assembly is available from Kontron Embedded Modules for the COMe-cSP2. The heatspreader
plate on top of this assembly is NOT a heat sink. It works as a COM Express-standard thermal interface to use with a
heat sink or other cooling device.
External cooling must be provided to maintain the heat-spreader plate at proper operating temperatures. Under
worst-case conditions, the cooling mechanism must maintain an ambient air and heat-spreader plate temperature of
60° C or less.
The aluminum slugs and thermal pads on the underside of the heat-spreader assembly implement thermal interfaces
between the heat spreader plate and the major heat-generating components on the COMe-cSP2. About 80 percent of
the power dissipated within the module is conducted to the heat-spreader plate and can be removed by the cooling
solution.
You can use many thermal-management solutions with the heat-spreader plates, including active and passive
approaches. The optimum cooling solution varies, depending on the COM Express® application and environmental
conditions. Please see the COM Express® Design Guide for further information on thermal management.
6.2 Heatspreader Dimensions
Documentation of COMe-cSP2 heatspreader is available in Kontron‘s customer section.